MicroMag 2900/3900 Data File (Series 0016.002)
Remanence curves:  DCD

INSTRUMENT
Configuration                   VSM
Temperature control             None
Hardware version                0004
Software version                01/29/2013
Units of measure                Hybrid SI
Temperature in                  Kelvin

SAMPLE
Mass                            N/A
Volume                          N/A
Demagnetizing factor            N/A

SETTINGS
Field range                     N/A
Field (command)                 N/A
Moment range                   +200.0000E-06
Averaging time                 +100.0000E-03
Temperature (command)           N/A
Tmprtr difference correction    No
Orientation                     0.000000E+00
Vibration amplitude             1.0
Calibration factor             +5.102946E+00
Operating frequency            +83.00000E+00

MEASUREMENT
Description                    ""
Field (measured)                N/A
Temperature (measured)          N/A
Averages (completed)            N/A
Measured on                     05/16/2023  22:43
Elapsed time                   +101.3255E+00

PROCESSING
Background subtraction          No
Delta-m processing              No
Demagnetizing factor            No
Normalization                   No
Normalization factor            N/A
Offset (field)                  No
Offset (moment)                 No
Pole saturation                 No
Slope correction                No

VIEWPORT
Left                           -100.0000E-03
Right                          +100.0000E-03
Bottom                         -200.0000E-06
Top                            +200.0000E-06
Show X-axis?                    Yes
Show Y-axis?                    Yes

CHARACTERIZATION
Initial slope                   N/A
Saturation                      N/A
Remanence                      +15.97299E-06
Coercivity (direct)             N/A
Coercivity (remanent)          +24.90558E-03
S* (direct)                     N/A
S* (DCD)                       -166.5133E-03

SCRIPT
Include IRM?                    No
Include DCD?                    Yes
Include direct moment?          No
Demagnetize before measuring?   No
Field sequence                  Nonlinear
Initial (non-zero) field       +10.00000E-06
Final field                    +100.0000E-03
Number of points/curve          30
Pause at applied field         +100.0000E-03
Slew rate to applied field     +1.000000E+00
Averaging time                 +100.0000E-03
Saturating field               +500.0000E-03
Pause at saturating field      +1.000000E+00
Saturating field applied        Only once
Slew rate to saturating field  +1.000000E+00
Pause at zero field            +100.0000E-03
Slew rate to zero field        +1.000000E+00
Number of segments              1
Number of data                  30

Segment   Averaging      Initial        Field         Final                    Final 
 Number      Time         Field       Increment       Field         Pause      Index 
             (s)           (T)           (T)           (T)           (s)     
0000001,+100.0000E-03, 0.000000E+00,+10.00000E-06,-100.0000E-03,+100.0000E-03,0000030

                           
    Field       Remanence  
     (T)          (Am)    
+434.0312E-09,+15.97299E-06
-10.36042E-06,+15.96790E-06
-23.51993E-06,+15.96311E-06
-41.17361E-06,+15.95153E-06
-62.91389E-06,+15.94364E-06
-93.85377E-06,+15.93265E-06
-134.4611E-06,+15.91115E-06
-187.0083E-06,+15.88357E-06
-257.3382E-06,+15.85232E-06
-348.9402E-06,+15.81106E-06
-471.5091E-06,+15.73718E-06
-631.8195E-06,+15.65486E-06
-845.2807E-06,+15.54189E-06
-1.126775E-03,+15.38414E-06
-1.498599E-03,+15.17981E-06
-1.989280E-03,+14.90657E-06
-2.638829E-03,+14.53896E-06
-3.492373E-03,+14.03400E-06
-4.625002E-03,+13.36210E-06
-6.119389E-03,+12.44031E-06
-8.100125E-03,+11.16133E-06
-10.71534E-03,+9.397564E-06
-14.16150E-03,+6.980118E-06
-18.71976E-03,+3.825711E-06
-24.74135E-03,+81.73504E-09
-32.70105E-03,-3.879698E-06
-43.21818E-03,-7.613360E-06
-57.10406E-03,-10.75024E-06
-75.42658E-03,-13.09374E-06
-99.70195E-03,-14.61047E-06

MicroMag 2900/3900 Data File ends